MANUFACTURING REFERENCE · FT / ST

Metal stamping tolerances calculator

Look up a reference tolerance by stamping process, feature size and sheet thickness, then see its total width, signed deviations and dimensional limits in mm or inches.

Look up a stamping tolerance

Choose the process, measured feature and sheet thickness. The suggested FT/ST grade comes from the site’s legacy mapping.

Default limits are a symmetric illustration. For blanked outside dimensions a below-nominal band may be appropriate, and for inside dimensions an above-nominal band; use the signed deviations actually specified on your drawing. No automatic grade substitution.

What are the tolerances for stamped sheet metal?

There is no single tolerance for every stamped part. Select the forming or blanking process, the measured feature, its basic dimension and sheet thickness. This tool returns a legacy table width T for the suggested FT or ST grade. A symmetric allocation gives deviations of −T/2 and +T/2; a one-sided allocation places the same width entirely above or below nominal.

For example, the stored FT1 reference for a 25 mm deep-drawn diameter in 1 mm sheet is T = 0.04 mm. A symmetric illustration is ±0.02 mm, giving limits of 24.98–25.02 mm. T = 0.04 mm does not mean ±0.04 mm.

Inputs and output meaning
ParameterUse in this toolCheck on the drawing
Basic dimension D, H or LThe nominal feature being evaluatedOutside/inside size, drawn height, flange length or a center/edge distance
Sheet thickness tSelects the thickness band; not a calculated thickness toleranceIncoming stock specification and any thinning after forming
FT / ST gradeFT = formed features; ST = blanked features, as stored in the legacy mappingThe required grade and feature category; the suggestion is not a supplier guarantee
Total width TUpper limit minus lower limitThe actual signed allocation specified by the drawing
Stamping feature dimensions and sheet thicknessA drawn cup shows diameter D and height H. A flat blank shows length L, hole center distance C, hole edge distance E and thickness t in a separate side view. Illustrative geometry, not to scale.DHDrawn cupLCEtSide view
Choose the actual measured feature. Hole edge distance E is measured edge-to-edge in this sketch; verify the definition used in your drawing and source specification. Original schematic, not to scale.

Process-to-grade suggestions in the stored table

Seven processes and 20 feature mappings are available. These suggestions are historical site data, not an automatic selection of a contractual standard class. No row is silently changed to a coarser grade, and missing FT cells are never replaced with ST values.

Supported process and feature combinations
ProcessFeatureSuggested grade
Deep DrawingDiameterFT1
Deep DrawingHeightFT3
Flanged Deep DrawingDiameterFT1
Flanged Deep DrawingHeightFT5
BendingLengthFT5
Other Forming MethodsDiameterFT1
Other Forming MethodsHeightFT3
Other Forming MethodsLengthFT4
Precision BlankingExternal ShapeST1
Precision BlankingInternal ShapeST1
Precision BlankingHole Center DistanceST1
Precision BlankingHole Edge DistanceST4
Standard Flat BlankingExternal ShapeST2
Standard Flat BlankingInternal ShapeST2
Standard Flat BlankingHole Center DistanceST2
Standard Flat BlankingHole Edge DistanceST4
Formed Stamping BlankingExternal ShapeST5
Formed Stamping BlankingInternal ShapeST4
Formed Stamping BlankingHole Center DistanceST4
Formed Stamping BlankingHole Edge DistanceST6

Range and endpoint rules

The stored table spans basic dimensions 0.5–6300 mm and sheet thickness greater than 0 to 100 mm. Not every size/thickness/grade combination has a value. Exact shared endpoints use the first stored matching row, preserving the existing lower-band selection. For example, 25 mm remains in the 10–25 mm row, and 1 mm thickness remains in the 0.5–1 mm row. Missing cells produce “no numeric reference value”.

Both inputs and the result convert using 1 inch = 25.4 mm. Switching units preserves the physical dimensions and clears the result until you recalculate. Values shown in the result belong to the saved input snapshot, not to later edits.

Three reproducible reference examples

These examples test the stored software model and allocation arithmetic. They are not measured production trials or independent standard certification.

Example 1: Deep Drawing · Diameter

Reference result · FT1

T = 0.04 mm total tolerance width

Deep Drawing · Diameter · nominal 25 mm · sheet thickness 1 mm

Allocation chosen: Symmetric: −T/2 to +T/2. This converts the reference width into limits; confirm the allocation on the drawing.

Lower deviation
-0.02 mm
Upper deviation
+0.02 mm
Lower limit
24.98 mm
Upper limit
25.02 mm

Matched table row: basic dimension 10–25 mm; thickness 0.5–1 mm. Exact shared endpoints use the preceding row. Input converted to 25 mm / 1 mm.

Legacy reference table and process-to-grade suggestion. This is a dimensional allowance, not measured process capability, a guaranteed supplier tolerance, or a complete standard verification.

Load example 1 in the calculator

Example 2: Bending · Length

Reference result · FT5

T = 0.5 mm total tolerance width

Bending · Length · nominal 50 mm · sheet thickness 2 mm

Allocation chosen: Symmetric: −T/2 to +T/2. This converts the reference width into limits; confirm the allocation on the drawing.

Lower deviation
-0.25 mm
Upper deviation
+0.25 mm
Lower limit
49.75 mm
Upper limit
50.25 mm

Matched table row: basic dimension 25–63 mm; thickness 1–3 mm. Exact shared endpoints use the preceding row. Input converted to 50 mm / 2 mm.

Legacy reference table and process-to-grade suggestion. This is a dimensional allowance, not measured process capability, a guaranteed supplier tolerance, or a complete standard verification.

Load example 2 in the calculator

Example 3: Standard Flat Blanking · External Shape

Reference result · ST2

T = 0.09 mm total tolerance width

Standard Flat Blanking · External Shape · nominal 100 mm · sheet thickness 1 mm

Allocation chosen: Below nominal: −T to 0. This converts the reference width into limits; confirm the allocation on the drawing.

Lower deviation
-0.09 mm
Upper deviation
0 mm
Lower limit
99.91 mm
Upper limit
100 mm

Matched table row: basic dimension 63–160 mm; thickness 0.5–1 mm. Exact shared endpoints use the preceding row. Input converted to 100 mm / 1 mm.

Legacy reference table and process-to-grade suggestion. This is a dimensional allowance, not measured process capability, a guaranteed supplier tolerance, or a complete standard verification.

Load example 3 in the calculator

From allowance to a manufacturing decision

  1. Identify functional dimensions, datums and the measurement condition before applying a tolerance.
  2. Separate blanked edges and holes from dimensions across bends or drawn walls. Tool wear, material variation and elastic recovery affect these features differently.
  3. Use the table as a starting reference. Agree the class, signed deviations, stock tolerance, burr direction, inspection method and any secondary operations with the manufacturer.
  4. Confirm repeatability using representative production measurements and an agreed capability study. This calculator does not calculate Cp/Cpk, press capability, burr height, springback compensation, bend angle or flatness.

Tighter limits can require more demanding tooling, inspection or secondary operations. Retain tight requirements where assembly or performance needs them, and review nonfunctional dimensions during DFM.

Sources, standard scope and maintenance

Page and software review: 16 November 2026. Numeric source: this site’s existing 42-row tolerance reference and 20-entry process mapping. Original numeric values are retained. Their original publication, edition, full transcription accuracy and original independent reviewer are not confirmed.

The official GB/T 13914-2013 catalog identifies “Tolerance of dimensions for stamping parts” as current at this review. The catalog check does not certify that these legacy tables implement that edition. This calculator is not presented as a verified GB/T, DIN or ISO implementation. Consult the applicable licensed standard and agreed drawing before acceptance decisions.

Manufacturing context: Dayton Rogers on feature location, tooling and tolerance and Kenmode on functional requirements and tolerance costs. Their supplier figures and diagrams are not used as this calculator’s numeric data.